鍋爐這種設備是要很(hěn)好的維護才能更好的被使用!
鍋(guō)爐使用中(zhōng)應定期清理水溫及水位探頭,定(dìng)期檢查除垢;開水爐(lú)需(xū)定期疏通爐體開水(shuǐ)出水口及出水管道及水嘴。每天須至少進行一次排汙。
排(pái)汙辦法:排汙前鍋爐水位處於正常高水位,鍋爐壓力在0.1-0.2MPA時進行,本著“勤排、少排、均勻排”的原則(每天至少一次),短促間斷進(jìn)行,即排汙閥開後即關,關後(hòu)再開、如此重複(fù)數次,待水位處於正常低水位即可。切記不得將鍋爐排空。
鍋爐的壓力表(biǎo)、an全閥等安全(quán)附件應定期校驗以保(bǎo)證其可靠性(xìng)(壓力(lì)表(biǎo)每半年至少一(yī)次,an全閥每一年(nián)至少一次)。
Boiler This equipment is to be well maintained to be better used!
Boiler should be regularly cleaned water temperature and water level probe, regularly check descaling; boilers need to regularly open the furnace water outlet and outlet pipes and faucets. Drain must be done at least once a day.
Sewage disposal methods: before the sewage boiler water level is at a normal high water level, the boiler pressure at 0.1-0.2MPA carried out, the spirit of "row row, less row, even row" principle (at least once a day), short interruption, After the close, off and then open, so repeated several times until the water level at the normal low water level can be. Remember not to empty the boiler.
Boiler pressure gauges, safety valves and other safety accessories should be regularly verified to ensure its reliability (pressure gauge at least once every six months, safety valve at least once a year).